High-Risk System · Explosion-Proof Dedusting · 4 kW

Novavac XZone 40

Explosion-proof dust extraction for high-risk industrial dust control.

A 4 kW high-risk dust extraction system built for industrial environments where combustible dust, static risk, and explosion-control requirements demand more than standard air extraction.

Explosion-proof dedusting platform
Built for combustible-dust environments
4 kW three-phase performance
3800 m³/h airflow
Automatic jet pulse filter cleaning
16 m² filter surface
Antistatic filtration
Grounding hardware
Explosion-proof centrifugal fan
Compliance System™ compatible

Explosion-proof design · Antistatic filtration · 4 kW three-phase · 3800 m³/h airflow · QR compliance dossier

01 · Range Positioning

The 4 kW system in the XZone range

The 4 kW system in the Novavac XZone range.

The Novavac XZone 40 is the 4 kW high-risk fixed extraction system in the Novavac XZone range. It is built for industrial environments where standard extraction is not enough because the dust risk is more serious.

Use it when your operation involves combustible dust, hazardous particulate, static risk, or industrial processes where explosion-proof components, grounding, and antistatic filtration are required.

This is not a standard Air Extraction system. It is a high-risk dust extraction system for environments where ordinary equipment is not acceptable.

02 · B2B Sales Positioning

For businesses that need high-risk protection without oversizing

The middle ground: serious high-risk control, properly sized.

Not every high-risk environment needs the largest system. But every high-risk environment needs the correct system category. XZone 40 is built for businesses that need explosion-proof dedusting capability, but do not require the higher airflow and capacity of XZone 55.

Risk A · Under-control

Choose standard extraction

…and you may under-control the hazard. Not safe. Not compliant.

Risk B · Overspend

Choose an oversized system

…and you may overspend on capacity you do not need.

★ Correct tier

Choose the correct XZone tier

…and you control risk without overbuying. That is the XZone 40 case.

The XZone 40 promise

XZone 40 exists for that middle ground: serious high-risk dust control, properly sized.

03 · What It Solves

High-risk dust ≠ ordinary dust

High-risk dust cannot be treated like ordinary dust.

Combustible dust changes the equipment decision. Once ignition risk, static build-up, or explosion-risk conditions are involved, the question is no longer only "how much airflow do we need?"

The real question

"Is this system suitable for the risk category?"

01.
Combustible dust extraction requirements
02.
Static discharge risk through grounding and antistatic filtration
03.
Dust concentration control in industrial environments
04.
Fixed source capture in higher-risk production areas
05.
Unsafe reliance on standard dust collectors
06.
Filter loading during repeated dust generation
07.
The need for explosion-proof system components engineered around ignition-risk control, not just airflow.

When the dust risk changes, the system category must change.

04 · Best Fit

Best for controlled high-risk fixed dust sources

Best for controlled high-risk fixed dust sources.

XZone 40 is designed for industrial operations where dust extraction must be matched to combustible-dust or explosion-risk conditions, but the application does not require the higher capacity of XZone 55.

★ Best for

When XZone 40 is the right fit

  • Combustible dust environments
  • Smaller high-risk industrial production areas
  • Fixed dust-generating processes
  • Machinery with ignition-risk concerns
  • Manufacturing handling combustible or reactive particles
  • Processing requiring antistatic and grounded extraction
  • Facilities upgrading from standard collectors into high-risk equipment
  • Environments where Air 40 is not acceptable due to risk category
  • Applications where XZone 55 may be more than required
⤷ Not the right fit for

When XZone 40 is the wrong tool

  • Ordinary low-risk workshop dust
  • Mobile tool-connected silica work
  • Sealed Longopac hazardous dust disposal as the main priority
  • Basic fixed source capture where Air 40 is enough
  • High-volume high-risk dust loads that require XZone 55
  • Bulk storage and discharge applications
  • Buyers looking for the cheapest dust collector
  • Any application where the dust risk has not been assessed
Upgrade / Downgrade Logic

Choose the category that matches the actual risk profile.

↑ Step up

If your high-risk dust load is larger → Novavac XZone 55.

⤷ Different category

If fixed but not combustible / high-risk → Air 40 or Air 55.

⤷ Different category

If priority is sealed silica disposal → Silica Safety Systems.

05 · Core Features

Built for high-risk dust control

Built for high-risk dust control, not standard extraction.

Nine engineered features that put XZone 40 in the high-risk category — and keep it out of the standard dust collector aisle.

F.01 · Platform

Explosion-proof system design

Built on an explosion-proof dedusting platform for high-risk industrial dust environments. Equipment designed around ignition-risk control, not just airflow.

F.02 · Filtration

Antistatic filtration

Manages static-related risk during dust extraction. For combustible dust, static control is not an optional upgrade. It is part of the safety strategy.

F.03 · Safety

Grounding hardware

Supports safer operation by helping manage static discharge risk. In high-risk environments, ignoring grounding is reckless.

F.04 · Fan

Explosion-proof centrifugal fan

Supports safer extraction in environments where standard fan components may not be suitable.

F.05 · Airflow

3800 m³/h airflow

Strong fixed extraction for controlled high-risk dust sources. Same airflow class as Air 40 — completely different risk configuration.

F.06 · Power

4 kW three-phase performance

Performance for serious high-risk extraction without stepping immediately into the larger XZone 55 tier.

F.07 · Maintenance

Automatic jet pulse cleaning

Maintains airflow and filter performance during operation. Inconsistent extraction is not just inefficient — it becomes a safety weakness.

F.08 · Filter

16 m² filter surface

Supports high-risk dust capture during repeated use. More filter surface helps maintain airflow and manage dust loading more effectively.

F.09 · Collection

35L collection bin

Practical dust collection in fixed industrial environments. Not Longopac sealed disposal — explosion-proof dedusting with collection-bin recovery.

06 · Compliance System™

QR-based compliance layer

Compatible with the Novavac Compliance System™.

XZone 40 can be integrated with the QR-based compliance layer used across Novavac systems — giving each unit a serial-tracked digital dossier designed to support correct use, documentation, maintenance, and audit readiness.

  • QR-based access to machine documentation
  • On-site usage guidance
  • Maintenance and filter tracking
  • Safe dust handling procedures
  • Clearer accountability for operators and supervisors
  • Easier access to high-risk system documentation
Positioning line

XZone 40 controls high-risk dust. The compliance layer documents that the system is being used and maintained correctly.

Unit IDNVX40-•••••
★ Compliance
Scan for dossier
Docs · Maintenance · Filter log

07 · Specifications

Engineering datasheet

Novavac XZone 40 specifications.

Spec table XZone 40
System category
High-Risk Systems
System type
Explosion-proof dedusting
Range position
4 kW high-risk fixed extraction
Power supply
380V / 50Hz three phase
Power output
4 kW
Vacuum pressure
3000 mmH₂O
Airflow
3800 m³/h
Filter surface
16 m²
Filter cleaning
Automatic jet pulse
Filtration
Antistatic filter
Fan type
Explosion-proof centrifugal
Safety configuration
Ex-proof switch + grounding
Collection system
Collection bin
Collection capacity
35 L
Noise level
74 dB
Dimensions
1070 × 800 × 1900 mm
Weight
145 kg
Recommended use
Combustible-dust / high-risk industrial
4kW
Three-phase power380V · 50Hz · 4 kW
3800m³/h
Airflow capacitySame class as Air 40
16
Filter surfaceAntistatic · Jet pulse
35L
Collection binNot Longopac
Source technical base: DUCEX-22/40S explosion-proof dedusting specification, 4 kW configuration.

08 · Where It Sits in the Range

Decision matrix

High-risk equipment, but not maximum capacity.

XZone 40 sits inside the Novavac High-Risk Systems range. It is the correct choice when the environment requires explosion-proof system design, antistatic filtration, grounding, and fixed high-risk dust extraction — but the demand does not justify XZone 55.

★ Choose this

XZone 40

High-risk · 4 kW

  • Explosion-proof dedusting
  • Combustible dust extraction
  • High-risk industrial dust control
  • 4 kW three-phase performance
  • 3800 m³/h airflow
  • Antistatic filtration
  • Grounding hardware
  • Automatic jet pulse cleaning
  • 16 m² filter surface
  • Compliance compatibility
↑ Step up

XZone 55

High-risk · 5.5 kW

  • Higher airflow
  • Larger filter surface
  • Higher dust volume
  • More demanding extraction
  • XZone 55-level performance
⤷ Air 40

Air 40

Air Extraction · 4 kW

  • Fixed source capture
  • Non-combustible production dust
  • Standard Air Extraction
  • Same airflow class
  • No explosion-proof requirements
⤷ Different category

Other ranges

Silica · Mobile · Bulk

  • Sealed silica dust disposal
  • Mobile production air extraction
  • Bulk dust storage and discharge
  • Tool-connected hazardous extraction

Compare the full High-Risk Systems range side by side.

Compare High-Risk Systems
link href="https://fonts.googleapis.com/css2?family=Archivo:wght@600;700;800;900&family=Inter:wght@400;500;600&display=swap" rel="stylesheet">

09 · XZone 40 vs Air 40

Same airflow class, different risk category

XZone 40 or Air 40? Same airflow class. Different risk category.

Air 40 and XZone 40 are similar in performance class — but they are not the same product category. Buying around airflow alone is how operations end up with the wrong system in the wrong environment.

Air Extraction

Air 40

Standard fixed extraction

Category
Air Extraction
System type
Standard fixed extraction
Best for
Fixed non-combustible production dust
Power
4 kW
Airflow
3800 m³/h
Filter surface
16 m²
Safety design
Standard fixed extraction
Buyer priority
Source capture
★ This page · High-Risk

XZone 40

Explosion-proof dedusting

Category
High-Risk Systems
System type
Explosion-proof dedusting
Best for
Combustible-dust and high-risk industrial
Power
4 kW
Airflow
3800 m³/h
Filter surface
16 m²
Safety design
Ex-proof, antistatic, grounded
Buyer priority
Risk-controlled extraction

Do not buy Air 40 when the environment requires XZone. That is not saving money. That is creating risk.

10 · XZone 40 vs XZone 55

Same range, different capacity

XZone 40 or XZone 55? Correct risk category, different capacity.

Both are high-risk systems. The difference is capacity. Choose XZone 40 when the risk category is high but the dust volume and extraction demand are moderate. Choose XZone 55 when the dust volume, operating intensity, or source-capture requirement is higher.

Capacity comparison XZone range
Power
XZone 40
4 kW
XZone 55
5.5 kW
Airflow
XZone 40
3800 m³/h
XZone 55
5800 m³/h
Filter surface
XZone 40
16 m²
XZone 55
24 m²
Collection
XZone 40
35 L
XZone 55
50 L
★ This page · 4 kW

XZone 40

For facilities needing high-risk controls without overbuying. Same explosion-proof platform — designed for controlled high-risk fixed dust sources where 4 kW class is the right size.

Main reason to choose: correct risk category at lower capacity.

↑ Step up · 5.5 kW

XZone 55

For operations needing stronger high-risk capacity. Same explosion-proof architecture — built for higher-volume high-risk fixed dust sources, more airflow, heavier source capture.

Main reason to choose: more airflow and capacity for higher-demand high-risk dust.

Do not choose based only on price. In high-risk environments, the system must be sized around both risk and dust load.

11 · XZone 40 vs Silica Safety

Combustible risk vs sealed hazardous disposal

XZone 40 or Silica Safety? Combustible risk vs sealed hazardous dust disposal.

Two different problems. Two different system categories. Get the diagnosis right before getting the system right.

★ This page

XZone 40

High-Risk Systems

Category
High-Risk Systems
Main role
Combustible / high-risk dust extraction
Best for
Explosion-risk industrial environments
Collection
Collection bin · 35L
Buyer priority
Explosion-risk controls
Typical setup
Fixed industrial extraction
vs
⤷ Different category

Silica Safety

Sealed hazardous dust

Category
Silica Safety
Main role
Sealed hazardous fine dust extraction & disposal
Best for
Tool-connected silica and fine dust work
Collection
Longopac continuous bagging
Buyer priority
Exposure control & sealed disposal
Typical setup
Mobile / tool-connected extraction
Diagnosis decides the category

If the issue is silica exposure → Silica Safety. If the issue is combustible / explosion-risk → XZone.

Silica Safety Systems are built around sealed hazardous dust extraction and Longopac disposal. XZone 40 is built for higher-risk environments where combustible dust, static, grounding, and explosion-proof system design matter.

12 · XZone 40 vs Bulk Handling

Risk control vs volume handling

XZone 40 or Bulk Handling? Risk control vs volume handling.

Bulk systems solve a volume problem. XZone systems solve a risk problem. The category you choose should match the problem — not the size of the tank.

★ Risk problem

XZone 40

Category
High-Risk Systems
Main role
High-risk dust extraction
Best for
Combustible / explosion-risk environments
Collection
35L collection bin
Buyer priority
Safety controls & risk suitability
Typical setup
High-risk industrial extraction
⤷ Volume problem

Bulk Handling

Category
Bulk Handling
Main role
Recover, store, and discharge material
Best for
Large-volume material recovery
Collection
600L hopper
Buyer priority
Capacity, storage, and discharge
Typical setup
Silo recovery & process integration
12
The diagnosis

Bulk solves a volume problem. XZone solves a risk problem.

If your main issue is storage capacity and discharge — Bulk Handling may be the better category. If your dust is combustible or the process involves explosion-risk conditions, XZone must be considered before volume alone. Choosing based only on tank size is how businesses make dangerous decisions.

13 · Industry Applications

Where XZone 40 belongs

Built for high-risk dust across multiple industries.

The XZone 40 is designed for industrial environments where dust is not just a nuisance, but a safety-critical risk.

App.01

Manufacturing & processing

For industrial processes that generate combustible, reactive, or hazardous particles requiring controlled extraction.

App.02

Wood, plastics, metals & composites

For dust-generating environments where combustible dust risk may exist — fine particulate at scale.

App.03

Chemical & material processing

For environments where dust type and ignition risk must be assessed carefully before equipment selection.

App.04

Fabrication & finishing

For grinding, cutting, or finishing processes that produce higher-risk dust at fixed sources.

App.05

Mining & minerals

For high-risk dust extraction where combustible or hazardous dust conditions may apply on-site.

App.06

Industrial maintenance & cleaning

For facilities requiring extraction systems matched to the site risk profile, not generic specs.

App.07 · Critical

Zone-rated industrial operations

For areas where standard extraction equipment is not appropriate — Ex-classified zones, ATEX-aware operations, and any environment where ignition control is built into the standard operating procedure.

14 · What's Included

Complete high-risk extraction system

Supplied as a complete high-risk extraction system.

Not a standard dust collector with a stronger label — a system, accessories, compliance dossier, and the support layer ready to operate from day one.

Included with every XZone 40
  • Novavac XZone 40 high-risk extraction unit
  • Antistatic filtration setup
  • Automatic jet pulse filter cleaning system
  • Explosion-proof centrifugal fan configuration
  • Explosion-proof switch configuration
  • Grounding hardware
  • 35L collection bin
  • Connection kit
  • High-risk application guidance
  • QR compliance dossier
  • Machine documentation
  • User guidance
  • 12-month warranty
  • Australia-wide delivery
The strong line

No standard extractor pretending to be high-risk equipment. No casual claims. No guessing when combustible dust is involved.

15 · Buying Process

Confirm before you buy

Confirm the right high-risk system before you buy.

The XZone 40 is a serious high-risk system, but correct selection depends on dust type, process conditions, site layout, and risk classification.

If risk is lower

Air 40 may be enough

If demand is higher

XZone 55 may be required

If sealed silica disposal

Silica Safety may be better

If bulk material recovery

Bulk Handling may be better

1

Tell us about your dust and process

We assess dust type, source, volume, operating environment, and risk profile.

2

Confirm the right system category

XZone 40, XZone 55, Air Extraction, Silica Safety, or Bulk Handling.

3

Review high-risk requirements

Combustible dust, static, area classification, or Ex requirements.

4

Prepare your system

Unit supplied with required accessories, documentation, and compliance layer.

5

Put it into operation

Your team receives a system designed to be used correctly from day one.

Get the right high-risk system. Properly sized.

Get a high-risk system assessment

16 · FAQ

Common XZone 40 questions

Frequently asked about XZone 40.

Q.01Is the Novavac XZone 40 explosion-proof?
Yes. XZone 40 is built on an explosion-proof dedusting platform with explosion-proof components, antistatic filtration, and grounding hardware.
Q.02Is XZone 40 the same as Air 40?
No. Air 40 is a standard fixed Air Extraction system. XZone 40 is a High-Risk System designed for combustible-dust and explosion-risk industrial environments.
Q.03Is XZone 40 suitable for combustible dust?
Yes — XZone 40 is engineered for combustible-dust environments. Final suitability depends on the dust type, process conditions, area classification, and site risk assessment.
Q.04Is XZone 40 suitable for silica dust?
It depends. It may be suitable in silica-related industrial environments where high-risk conditions apply, but ordinary silica exposure control is usually handled through Silica Safety or Air Extraction. The correct system depends on the actual risk profile.
Q.05Does XZone 40 use Longopac bagging?
No. XZone 40 uses a 35L collection bin. If sealed Longopac hazardous dust disposal is the priority, look at Silica Safety Systems.
Q.06Does XZone 40 have automatic filter cleaning?
Yes. XZone 40 uses automatic jet pulse filter cleaning to maintain airflow and filter performance during operation.
Q.07Is XZone 40 single-phase?
No. XZone 40 is a 380V three-phase system.
Q.08When should I choose XZone 55 instead?
Choose XZone 55 when the application requires higher airflow, larger filter surface, greater collection capacity, or stronger high-risk extraction performance.
Q.09When should I choose Air 40 instead?
Choose Air 40 when the dust source is fixed and requires extraction, but the environment does not require high-risk or explosion-proof system design.
Q.10Can I buy XZone 40 without an assessment?
You should not. For high-risk dust environments, system selection should be based on dust type, process, site conditions, and compliance requirements. Guessing is not acceptable.

Final · Talk to Novavac

XZone 40 · 4 kW Explosion-Proof Dedusting

Find out if XZone 40 is the right high-risk system for your operation.

If your environment involves combustible dust, explosion-risk conditions, or high-risk industrial dust — do not treat it like ordinary extraction. XZone 40 was built for that exact category, properly sized.

What XZone 40 brings to a high-risk environment
Power
4 kW
Airflow
3800 m³/h
Filter surface
16
Vacuum
3000 mmH₂O
Fan
Ex-proof
Filtration
Antistatic
Start the conversation

Get an XZone 40 high-risk system assessment.

15 minutes with our team confirms whether your dust type, process, zone classification, airflow requirements, power supply, and compliance needs match XZone 40 — explosion-proof system design, antistatic filtration, grounding hardware, and 3800 m³/h airflow for properly-sized high-risk control.

UK / AU support · Risk-profile review before quote · Three-phase certified · Compliance dossier included

B2B positioning verdict

The 4 kW high-risk extraction system for combustible-dust and explosion-risk environments where standard Air Extraction is not acceptable, but XZone 55 may be more than required.

Do not sell it as "Air 40 but explosion-proof." That sounds sloppy. Sell it around the real business case: same airflow class as Air 40, but built for a different risk category.